Articles Related to Precision
Individual Implants-Retained Maxillary and Mandibular Overdentures with Limited Vertical and Horizontal Space: A Clinical Case Report
Many clinical cases and literature review have revealed the implant-retained-overdentures (IROs) treatment success and predictability in elderly patients. According to the previous studies IROs treatment in maxillary arch prefer implants connected by a bar, while in mandibular arch the first option is to use un-splinted implants when 2 implants have been inserted. The aim of this clinical case report is to present prosthetic rehabilitation of both maxillary/mandibular arches with IROs. In this report four individual implants retained maxillary overdenture, and two individual implants retained mandibular overdenture were fabricated, due to the lack of sufficient vertical crown height space (CHS) and horizontal space. The patient was followed-up for more than 24 months with no complications.
Quantitative Analysis of 30 Drugs in Whole Blood by SPE and UHPLC-TOFMS
An Ultra-High Pressure Liquid Chromatography Time-of-Flight Mass Spectrometry (UHPLC-TOF-MS) method for quantitative analysis of 30 drugs in whole blood was developed and validated. The method was used for screening and quantification of common drugs and drugs of abuse in whole blood received from autopsy cases and living persons.
Development of a Stability Indicating UPLC-MS/MS Method for Rapid and Reliable Determination of Fenofibrate in Marketed Product (Lypanthyl® 200M) and Human Plasma
A reliable, fast, sensitive and selective Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS) method has been developed and validated for the determination of fenofibrate in marketed product (Lipanthyl) and human plasma. The chromatographic separation was performed on a reversed-phase Acquity®BEH C18 column (1.7 μm particle size, 50 mm x 2.1 mm ID) with an isocratic elution profile and mobile phase consisting of methanol and water (80:20, %, v/v). To achieve optimum chromatographic condition the influence of mobile phase composition and flow rate was investigated. The total chromatographic analysis time was as short as 2 min.
Editorial Board Members Related to Precision
Alain L Fymat
President/CEO and Professor
International Institute of Medicine and Science
Rancho Mirage
California
USA
International Institute of Medicine and Science
Rancho Mirage
California
USA
Shengwen Calvin Li
Faculty Scientist
Center for Neuroscience and Stem Cell Research
University of California-Irvine School of Medicine
United States
Center for Neuroscience and Stem Cell Research
University of California-Irvine School of Medicine
United States
Guanghua Yan
Assistant Professor
Department of Radiation Oncology
University of Florida
United States
Department of Radiation Oncology
University of Florida
United States
Yong He
Professor
College of Biosystems Engineering and Food Science
Zhejiang University
College of Biosystems Engineering and Food Science
Zhejiang University